    BTW, heres an interesting tidbit for yall, I think why many titans "dies end up dieing permanently" are infact because the DCDC modules burn out. After looking over the tech sheet, its easy to see why. If the ambient temp (surface temp of the inductor) reaches the 80-90's these are only rated for 25-30A to maintain their expected lifespan.
    The fact some folks run them at these temps 24/7 and draw over 40A through them, its easy to see why the DCDC's would die ....

    When vegas measured the temp of the inductor from the side, it measured about 55C , the webgui showed about just over 60C ... so there is a really small delta between the ambient temp & internal junction temp(webgui reading) of these DCDC's

    Meaning, if ur webgui shows 90C area, the inductor is probably not far behind, most likely running in the low 80's ... which means nowhere near 40A should be pulled from the DCDC at that point.

    What would be the safest Maximum DCDC temp setting on advance page of your mod regardless of the ambient temp? I currently set it at 90 and all dies run at 325, should I lower it?




    Ultimately its up to the user and their preferences of how long they want the machine to potentially last.
    Its hard to answer ur question definitively due to so many environment variables & operating conditions between cubes.
    What everyone needs is a laser temp reader to take temperature checks of the inductor on the DCDC modules while its hashing. If its true that the inductor is generally within 10C of the webgui stat then a SAFE MAX temp @ 40A is... between 70 & 75C, so webgui stat should no higher than 80-85C.

    Whats interesting is with more airflow these DCDC's are rated for more current safely at any given temp, even if the temp is the same vs less/no airflow.

    For example, temp of inductor 80C @ no airflow is safe up to 34A.  80C @ 2-3m/s of airflow is safe up to 40A
    At 100C inductor temp: 20A safe for no airflow, 30A safe for 3m/s of airflow

    Another facet of max life from DCDC's is keeping them at their rated 40A max or lower. I know most of mine in the titan @ 325mhz are at 40-41A ... which I imagine aint bad, but I think around 43A ur starting to really push it. The actual Current limiting function of the DCDC's kicks in at 46A

    This is the life expectancy of the DCDC's given everything is within spec:
    MTBF at 90% confidence level = 11.52 Mh