    OK ... go ahead and do a git pull, think I got the syntax nailed. It worked on my end for a fake hard reset & a live soft reset so... yeah

    Also, I made it so in my loop it will attempt a soft reset every 60 seconds up to 7 times, if it fails all those it will do a hard reset at that point.
    Now that my code is working, since that die of yours constantly shows 0 amps even with successful soft resets, it will succumb to my hard reset loop after it attempts 7 times. =(

    ok I'll try it out
    I can write a custom version for you that will tell the KNC loop to ignore the die u have clocked at 150mhz that way it snot constantly doing a hard reset on you every 20mins =) Let me know.

    let me see how it goes, I might take you up on that

    yeah, It lasted about 12 min before the hard reset, I wonder why it took 5 min before starting the resets?  maybe it initially has an amp reading??

    maybe create a file that can be edited with a custom list of dies to ignore??
    It takes about 5 mins before KNC's main loop flags the die for needing a reset(which sends it to my custom loop at that point) ... which is why previously when my code wasnt working correctly(before I fixed the syntax error) it it was just soft resetting every 6mins or so for you.

    Yeah, I may be able to setup a custom file for listing dies to ignore checking DCDC condition period.
    That will take a bit more research how to do, Im sure it isnt hard w/ grepping a text file =)